規(guī)格:詳見說明
所屬類型:其它儀器
品牌:科迪
C.4.2 Fill the container with the sodium chloridesolution (see C.2) using at least 1 litre of solution for every square decimetre of area of the stainless steel parts of the samples. Bring the container and contents to 60 °C ± 2 °C. Maintain at this temperature. Do not allow the temperature of the solution to exceed 62 °C at any time, even before the start of the test. Use a fresh sodium chloride solution for each test.
NOTE The temperature of the sodium chloride solution may be conveniently maintained at 60 °C ± 2 °C by positioning the apparatus in a thermostatically controlled water bath, the level of which is maintained at approximately the same level as that of the sodium chloride solution.
C.4.3 Place the test specimen in the rack and, in the case of knives with stainless steel handles, support the handles in such a way that they do not come into contact with the rack. Replace the cover.
C.4.4 Completely immerse and completely withdraw the test specimens from the solution at the rate of from two to three times per minute for 6 h.
C.4.5 At the conclusion of the test period, thoroughly wash and rinse the test specimens and examine for corrosion.
NOTE Products of corrosion that impede visual examination of corrosion pits should be removed by hand rubbing the surface of the cutlery with a stainless steel polishing paste applied with asoft cloth.
C.5 Expression of results Assess the size and number of pits per test specimen and the length of longitudinal cracks visually with the aid of a calibrated microscope or lens of at least four times magnification. Where two pits have obviously merged together they shall be assessed as
two separate pits.
NOTE The use of wires of diameter 0,4 mm and 0,75 mm respectively, placed in contact with the sample surface, provides a convenient method of assessing the size of pits with a hand lens.
針對上述ISO 8442-2:1998測試標(biāo)準(zhǔn)要求,科迪儀器生產(chǎn)出封閉式鹽水浸泡試驗箱和開放式鹽水浸泡試驗箱,保證測試產(chǎn)品浸入在鹽水中和停留在空氣中每分鐘2到3次,連續(xù)進(jìn)行6個小時的測試。
1、鹽水溫度要求:RT+5到60度可調(diào);
2、根據(jù)特定產(chǎn)品制作不同的夾具;
3、升降裝置做到每分鐘升降2到4次可調(diào);
4、加熱器不能以金屬材質(zhì)接觸鹽水。
東莞科迪儀器有限公司銷售科迪 詳見說明,針對科迪 詳見說明客戶提供相關(guān)咨詢服務(wù),需要了解科迪 詳見說明型號尺寸、重量、價格、安裝、維護(hù)等資料請與我們聯(lián)系。
東莞科迪儀器有限公司
經(jīng)營模式:生產(chǎn)貿(mào)易型
所在地區(qū):廣東 東莞